Eppendorf Rotor F-45-30-11, 30x1.5/2mL tubes, w/lidMax speed 20, 800 x g / 14, 000 rpm
Rotor F-45-30-11, 30x1.5/2mL tubes, w/lidMax speed 20, 800 x g / 14, 000 rpm
Product Description:
Centrifuge 5424 and 5424 R are laboratory standard. With their 24–place capacity and speed up to 21,130 × g they are perfectly equipped for all modern molecular biology applications in Eppendorf and PCR tubes.
Brochure
Manuals
Microcentrifuge 5424 | Microcentrifuge 5424 R | |
---|---|---|
Max g-force | 21,130 rcf | 21,130 rcf |
Speed range | 100-15,000 rpm | 100-15,000 rpm |
Capacity | 24 x 1.5/2.0 mL tubes | 24 x 1.5/2.0 mL tubes |
Number of rotors | 4 | 4 |
Capacity for 1.5 mL tubes | 24 | 24 |
Refrigeration | No | Yes |
Temperature control range | N/A | -10°C to 40°C |
Power supply | 120 V, 50/60 Hz | 120 V, 50/60 Hz |
Power consumption | max. 250 W | max. 350 W |
Acceleration time to max speed | 15 s (in FA-45-24-11) | 15 s (in FA-45-24-11) |
Braking time from max speed | 16 s (in FA-45-24-11) | 16 s (in FA-45-24-11) |
Acceleration/Brake speed settings | 2 | 2 |
Timer | 30 s to 9:59 h, with cont. mode | 30 s to 9:59 h, with cont. mode |
Noise level | <51 dB(A) | <54 dB(A) |
Dimensions (W x D x H) | 9.3 x 12.6 x 8.9 in / 24 x 32 x 23 cm /td> | 11.4 x 18.9 x 10 in / 29 x 48 x 26 cm /td> |
Height with lid open | 17 in / 44 cm /td> | 20 in / 51 cm /td> |
Weight | 29.5 lb / 13.4kg / d> | 46.3 lb / 21kg / d> |
Eppendorf 5424 / 5424 R Centrifuge features and benefits:
- Refrigerated Centrifuge 5424 R Features:
- Temperature range from -10 °C to +40 °C
- Guaranteed temperature of 4 °C at maximum rotational speed
- FastTemp function for quick pre-cooling of the centrifuge, e.g. from ~ 21 °C to 4 °C in only 8 minutes
- ECO power shut-off engages after 8 hours of non-use to reduce energy consumption (40 % overnight) and extend compressor life (can be deactivated)
- The patented compressor technology reduces vibrations and protects your samples
- Built-in condensation drain to eliminate water accumulation in the rotor chamber
- The Eppendorf 5424 and 5424 R Centrifuge is the replacement of Model 5415 D and 5415 R
5424 and 5424R Centrifuge Rotor Options
Eppendorf Kit rotor® (F?–?45?–?18?–?11?–?Kit) for 18 x spin columns and 1.5/2.0 mL tubes (max. 18,111 x g)
This unique rotor offers a solution for a common problem when working with MiniPrep spin column kits: open tube lids that shear off during the elution step. This problem traditionally occurs because standard rotors do not provide enough support for open tube lids during centrifugation. The Eppendorf Kit rotor is designed with an extended rim that serves as a rest for tube caps during centrifugation and protects them from shearing off. Your tube lids will not tear off anymore.