Eppendorf - Pipettes - ES-12-300
Research plus 12 channel pipette, 30-300 uL, orange operating button, for use with 300 uL pipette tips
Product Description:
The Eppendorf Research Plus Multichannel Pipette combines the spring-loaded tip cone, a secondary calibration option and improved volume display all in an ultra-light, fully autoclavable pipette. The spring-loaded tip cone saves your energy and time. No need for rocking, the spring guarantees a reproducible and safe tip fit. It provides increased user to user reproducibility for more uniform results among members of the lab.
Manuals
- Operating Manual for the Eppendorf Research plus
- User Adjustment for the Eppendorf Research plus
- Factory Adjustment for the Eppendorf Research plus
- Instructions for how to use the Pipette holder
- Chemical Resistance for the Eppendorf Research plus
- Leaflet for the Eppendorf Research plus
- Instructions for inserting the locking clip in the multichannel lower part
Specifications
Volume range | Volume | Systematic error | Random error | ||
Operating button grey for pipette tips 20 μL | |||||
0,5–10 μL | 0,5 μL | ±12,0% | ±0,06 μL | ±8,0% | ±0,04 μL |
1 μL | ±8,0% | ±0,08 μL | ±5,0% | ±0,05 μL | |
5 μL | ±4,0% | ±0,2 μL | ±2,0% | ±0,1 μL | |
10 μL | ±2,0% | ±0,2 μL | ±1,0% | ±0,1 μL | |
Operating button yellow for pipette tips 200 μL | |||||
10–100 μL | 10 μL | ±3,0% | ±0,3 μL | ±2,0% | ±0,2 μL |
50 μL | ±1,0% | ±0,5 μL | ±0,8% | ±0,4 μL | |
100 μL | ±0,8% | ±0,8 μL | ±0,3% | ±0,3 μL | |
Operating button orange for pipette tips 300 μL | |||||
30–300 μL | 30 μL | ±3,0% | ±0,9 μL | ±1,0% | ±0,3 μL |
150 μL | ±1,0% | ±1,5 μL | ±0,5% | ±0,75 μL | |
300 μL | ±0,6% | ±1,8 μL | ±0,3% | ±0,9 μL |
Eppendorf Research Plus Multichannel Pipette features and benefits:
- Air-displacement pipette for accurate pipetting of aqueous solutions.
- Feel the difference in weight and pipetting forces: the ultra-light mechanical pipette is designed according to the strict criteria of the Eppendorf PhysioCare Concept and limits the strain on your hand and arm.
- Spring-loaded tip cone for minimal tip attachment forces helps to reduce stress.
- The low tip ejection force can be as low as 3.6 N.
- Adjust your pipette in seconds for better accuracy when pipetting various difficult liquids like ethanol or even when pipetting at high altitudes. Return to factory adjustment without calibration.
- Autoclave the entire pipette or only the lower part according to your needs to ensure decontamination.
- Enjoy excellent flexibility and choice of variable volume 8 and 12 channel pipettes.
- Applications:
- Forward pipetting.
- Reverse pipetting.
- Removal of supernatants.
- Sample mixing.
- Phase extraction.
- Filling of plates, gels, and reaction vessels.